Return to HomeAbout our companyServices we provideContact Air to Ground









Series 13-14

SS Standard Features

  • Belt Driven General Pumps
  • Industrial Strength Electric Motors
  • High Limit Temp Control
  • Heavy Duty Electro Plated Fittings
  • Heating Coil Constructed of ASTM A53 Schedule 80 Steel Pipe
  • Quick Coil Access
  • Exclusive Chamber Insulation System
  • High Efficiency Beckett Burners
  • Fuel Oil Solenoid
  • Heavy Duty 1 1/4" OD Steel Tube Frame
  • Ground Spacing Frame Foot Pads
  • Heavy Duty Electrical Cord and Hose Hangers
  • Corrosion Proof Polyethylene Molded Fuel Tank
  • Corrosion Proof Polyethylene Float Tank with Chemical Metering
  • Trigger Gun Control
  • Insulated Wand with 4000 PSI Trigger Gun
  • 0° and 15° Quick Couple Nozzles
  • Powder Coated Painted Frame
  • Stainless Steel Outer Wrap
  • Ground Fault Circuit Interrupter Protection (Single Phase Units 30 Amps or Less)
  • ETL and CETL Listed to UL Std.-1776 and CSA Std. B140.11
  • 3/8" X 40' High Pressure Hose Assembly with Safety Hose Guards and Quick Coupler Ends
  • Racor Water Separating Fuel Filter
  • Adjustable Temperature/High Limit Control
  • Mag Wheels

SL Standard Features
Includes All Features of SS Plus:

  • Dual Lance Wand
  • 0°, 15°, 25°and 40° Quick Couple Nozzles
  • Time Delay Shut Down
  • Hour Meter
  • Magnetic Starter

Model 13-216 13-310 13-325 14-416 14-310C
Availability   SS   SS   SS   SS-SL   SS  
Flow Output (GPM)   2   3   3   4   3  
Pressure Ratings (PSI)   1600   1000   2500   1600   1000  
Max Output Temperature (°F)   190°   190°   190°   210°   210° Hi-Pr.
300° Steam
 
Cleaning Comparison Index (1)   7246   8593   12153   7556   8960/10613  
Motor Horsepower   2.3   2.3   5   4   2.3  
Electrical Requirements                      
Volt   115   115   230   230   115  
Amp   20   20   20   20   20  
Phase   1   1   1   1   1  
Oil Fired Burner System                      
Input BTU's   175,000   269,000   269,000   192,000   479,000  
Fuel Consumption (GPH) (2)   0.75   1.15   1.15   0.82   2.05  
Burner Fuel Tank Capacity   7.5   7.5   7.5   11   11  
Stack Size   7"   7"   7"   8"   8"  
Approx. Weight (lbs)   340   340   370   455   540  
Dimensions                      
Length   31.5"   31.5"   31.5"   37.5"   37.5"  
Width   24.5"   24.5"   24.5"   28.75"   28.75"  
Height   40"   40"   40"   44"   44"  


Model 14-320C 14-416 14-423 14-430 14-525
Availability   SS   SS-SL   SS-SL   SS-SL   SL  
Flow Output (GPM)   3   4   4   4   5  
Pressure Ratings (PSI)   2000   1600   2300   3000   2500  
Max Output Temperature (°F)   210° Hi-Pr.
300° Steam
  210°   210°   210°   210°  
Cleaning Comparison Index (1)   12672/15009   15112   18119   20693   23613  
Motor Horsepower   4   4   6   7.5 or 8   7.5 or 8  
Electrical Requirements                      
Volt   230   230   230   230   230  
Amp   20   20   30   40   40  
Phase   1   1   1   1   1  
Oil Fired Burner System                      
Input BTU's   479,000   384,000   384,000   384,000   437,000  
Fuel Consumption (GPH) (2)   2.05   1.65   1.65   1.65   1.87  
Burner Fuel Tank Capacity   11   11   11   11   11  
Stack Size   8"   8"   8"   8"   8"  
Approx. Weight (lbs)   550   455   535   545   605  
Dimensions                      
Length   37.5"   37.5"   37.5"   37.5"   37.5"  
Width   28.75"   28.75"   28.75"   28.75"   28.75"  
Height   44"   44"   44"   44"   44"  


Options

Model 14 Series
40 Amp GFCI Protection w/36' Cord

Call 1-888-495-9898 For Current Pricing!

Submit your order request on the FORM provided.


Back to top