Series 13-14
|
SS Standard Features
- Belt Driven General Pumps
- Industrial Strength Electric Motors
- High Limit Temp Control
- Heavy Duty Electro Plated Fittings
- Heating Coil Constructed of ASTM A53 Schedule 80 Steel Pipe
- Quick Coil Access
- Exclusive Chamber Insulation System
- High Efficiency Beckett Burners
- Fuel Oil Solenoid
- Heavy Duty 1 1/4" OD Steel Tube Frame
- Ground Spacing Frame Foot Pads
- Heavy Duty Electrical Cord and Hose Hangers
- Corrosion Proof Polyethylene Molded Fuel Tank
- Corrosion Proof Polyethylene Float Tank with Chemical Metering
- Trigger Gun Control
- Insulated Wand with 4000 PSI Trigger Gun
- 0° and 15° Quick Couple Nozzles
- Powder Coated Painted Frame
- Stainless Steel Outer Wrap
- Ground Fault Circuit Interrupter Protection (Single Phase Units 30 Amps or Less)
- ETL and CETL Listed to UL Std.-1776 and CSA Std. B140.11
- 3/8" X 40' High Pressure Hose Assembly with Safety Hose Guards and Quick Coupler
Ends
- Racor Water Separating Fuel Filter
- Adjustable Temperature/High Limit Control
- Mag Wheels
SL Standard Features
Includes All Features of SS Plus:
- Dual Lance Wand
- 0°, 15°, 25°and 40° Quick Couple Nozzles
- Time Delay Shut Down
- Hour Meter
- Magnetic Starter
|
Model
|
|
13-216
|
|
13-310
|
|
13-325
|
|
14-416
|
|
14-310C
|
|
|
Availability
|
|
SS
|
|
SS
|
|
SS
|
|
SS-SL
|
|
SS
|
|
|
Flow Output (GPM)
|
|
2
|
|
3
|
|
3
|
|
4
|
|
3
|
|
|
Pressure Ratings (PSI)
|
|
1600
|
|
1000
|
|
2500
|
|
1600
|
|
1000
|
|
|
Max Output Temperature (°F)
|
|
190°
|
|
190°
|
|
190°
|
|
210°
|
|
210° Hi-Pr.
300° Steam
|
|
|
Cleaning Comparison Index (1)
|
|
7246
|
|
8593
|
|
12153
|
|
7556
|
|
8960/10613
|
|
|
Motor Horsepower
|
|
2.3
|
|
2.3
|
|
5
|
|
4
|
|
2.3
|
|
|
Electrical Requirements
|
|
|
|
|
|
|
|
|
|
|
|
|
Volt
|
|
115
|
|
115
|
|
230
|
|
230
|
|
115
|
|
|
Amp
|
|
20
|
|
20
|
|
20
|
|
20
|
|
20
|
|
|
Phase
|
|
1
|
|
1
|
|
1
|
|
1
|
|
1
|
|
|
Oil Fired Burner System
|
|
|
|
|
|
|
|
|
|
|
|
|
Input BTU's
|
|
175,000
|
|
269,000
|
|
269,000
|
|
192,000
|
|
479,000
|
|
|
Fuel Consumption (GPH) (2)
|
|
0.75
|
|
1.15
|
|
1.15
|
|
0.82
|
|
2.05
|
|
|
Burner Fuel Tank Capacity
|
|
7.5
|
|
7.5
|
|
7.5
|
|
11
|
|
11
|
|
|
Stack Size
|
|
7"
|
|
7"
|
|
7"
|
|
8"
|
|
8"
|
|
|
Approx. Weight (lbs)
|
|
340
|
|
340
|
|
370
|
|
455
|
|
540
|
|
|
Dimensions
|
|
|
|
|
|
|
|
|
|
|
|
|
Length
|
|
31.5"
|
|
31.5"
|
|
31.5"
|
|
37.5"
|
|
37.5"
|
|
|
Width
|
|
24.5"
|
|
24.5"
|
|
24.5"
|
|
28.75"
|
|
28.75"
|
|
|
Height
|
|
40"
|
|
40"
|
|
40"
|
|
44"
|
|
44"
|
|
|
Model
|
|
14-320C
|
|
14-416
|
|
14-423
|
|
14-430
|
|
14-525
|
|
|
Availability
|
|
SS
|
|
SS-SL
|
|
SS-SL
|
|
SS-SL
|
|
SL
|
|
|
Flow Output (GPM)
|
|
3
|
|
4
|
|
4
|
|
4
|
|
5
|
|
|
Pressure Ratings (PSI)
|
|
2000
|
|
1600
|
|
2300
|
|
3000
|
|
2500
|
|
|
Max Output Temperature (°F)
|
|
210° Hi-Pr.
300° Steam
|
|
210°
|
|
210°
|
|
210°
|
|
210°
|
|
|
Cleaning Comparison Index (1)
|
|
12672/15009
|
|
15112
|
|
18119
|
|
20693
|
|
23613
|
|
|
Motor Horsepower
|
|
4
|
|
4
|
|
6
|
|
7.5 or 8
|
|
7.5 or 8
|
|
|
Electrical Requirements
|
|
|
|
|
|
|
|
|
|
|
|
|
Volt
|
|
230
|
|
230
|
|
230
|
|
230
|
|
230
|
|
|
Amp
|
|
20
|
|
20
|
|
30
|
|
40
|
|
40
|
|
|
Phase
|
|
1
|
|
1
|
|
1
|
|
1
|
|
1
|
|
|
Oil Fired Burner System
|
|
|
|
|
|
|
|
|
|
|
|
|
Input BTU's
|
|
479,000
|
|
384,000
|
|
384,000
|
|
384,000
|
|
437,000
|
|
|
Fuel Consumption (GPH) (2)
|
|
2.05
|
|
1.65
|
|
1.65
|
|
1.65
|
|
1.87
|
|
|
Burner Fuel Tank Capacity
|
|
11
|
|
11
|
|
11
|
|
11
|
|
11
|
|
|
Stack Size
|
|
8"
|
|
8"
|
|
8"
|
|
8"
|
|
8"
|
|
|
Approx. Weight (lbs)
|
|
550
|
|
455
|
|
535
|
|
545
|
|
605
|
|
|
Dimensions
|
|
|
|
|
|
|
|
|
|
|
|
|
Length
|
|
37.5"
|
|
37.5"
|
|
37.5"
|
|
37.5"
|
|
37.5"
|
|
|
Width
|
|
28.75"
|
|
28.75"
|
|
28.75"
|
|
28.75"
|
|
28.75"
|
|
|
Height
|
|
44"
|
|
44"
|
|
44"
|
|
44"
|
|
44"
|
|
Options
|
Model
|
|
|
|
14 Series
|
|
|
40 Amp GFCI Protection w/36' Cord
|
|
|
|
|
|
|
|
|
|
|
|
|
Call 1-888-495-9898 For Current Pricing!
Submit your order request on the FORM provided.
|
Back to top
|
|